<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Dept. of Physics</title>
<link>http://103.7.193.12:8080/xmlui/handle/123456789/40</link>
<description>DEPARTMENT OF PHYSICS (PHY)</description>
<pubDate>Sun, 25 Oct 2026 10:18:17 GMT</pubDate>
<dc:date>2026-10-25T10:18:17Z</dc:date>
<item>
<title>SIMULATION AND ANALYSIS OF TMDC SOLAR CELLS UNDER PROTON  RADIATION USING MONTE-CARLO METHODS, SCAPS, AND MACHINE  LEARNING TECHNIQUES</title>
<link>http://103.7.193.12:8080/xmlui/handle/123456789/2254</link>
<description>SIMULATION AND ANALYSIS OF TMDC SOLAR CELLS UNDER PROTON  RADIATION USING MONTE-CARLO METHODS, SCAPS, AND MACHINE  LEARNING TECHNIQUES
RAHMAN, NAIMUR
The space-based energy solutions are currently relying on expensive silicon-based solar cells. In recent &#13;
years, perovskite materials are also participating in this area as thin-film third generation solar cells. &#13;
However, these materials come with built-in drawbacks against radiation environments. To address this &#13;
issue, this research explores the possibility of using transition metal dichalcogenide (TMDC) materials as &#13;
absorbers in space solar cells. Proton radiation is a common and primary occurrence in space. Hence, we &#13;
investigated the effect of 0.15 MeV and 3 MeV proton radiation on four different TMDC heterojunction &#13;
thin-film solar cells with frequently used hole and electron transport materials. We have used SR-NIEL web &#13;
application, Monte-Carlo simulation toolkit SRIM, solar cell capacitance simulation SCAPS-1D, and &#13;
machine learning analysis for evaluating the energy loss, defect creation and performance analysis. For 0.15 &#13;
MeV and 3 MeV proton radiation, energy loss to ionization by ions, energy loss to ionization by recoils, &#13;
energy loss to phonons by ions, energy loss to phonons by recoils, energy from ions, vacancies by ions, and &#13;
replacement collisions are calculated. MoS2 and MoSe2 had higher power conversion efficiencies (PCE) of &#13;
28.16% and 28.11%, respectively, while WSe2 and WS2 had high short-circuit current densities (Jsc) of &#13;
39.36 mA/cm2 and 35.15 mA/cm2, respectively, under standard operating conditions (AM 1.5G, 1000 W/m2 &#13;
incident photon flux). However, when exposed to 0.15 MeV proton radiation, the performance of all devices &#13;
significantly decreased. MoSe2 and WS2 had relatively higher PCEs of 19.47% and 17.01%, respectively, &#13;
compared to WSe2 and MoS2, indicating some resistance to radiation-induced deterioration. Machine &#13;
learning predictions revealed that WS2 and WSe2 are more sensitive to proton radiation than MoSe2 and &#13;
MoS2 absorbers. This implies that, despite their possibility for high Jsc and efficient power generation, WS2 &#13;
and WSe2-based solar cells may be less suitable for areas with high proton radiation, as their performance &#13;
can decrease rapidly under such conditions. MoSe2 and MoS2 absorber-based solar cells, on the other hand, &#13;
appear to be more resistant to the negative effects of proton radiation, making them better candidates for &#13;
use in radiation-rich areas. These findings emphasize the relevance of material robustness to radiation when &#13;
building solar cells for space or radiation environments, as well as the promise of MoSe2 and MoS2 &#13;
absorbers in such applications.
SIMULATION AND ANALYSIS OF TMDC SOLAR CELLS UNDER PROTON &#13;
RADIATION USING MONTE-CARLO METHODS, SCAPS, AND MACHINE &#13;
LEARNING TECHNIQUES; &#13;
A Thesis Submitted in partial fulfillment of the requirements for the degree of &#13;
Master of Science (MS) in the Department of Physics, Hajee Mohammad Danesh &#13;
Science and Technology University, Dinajpur-5200 &#13;
Submitted By &#13;
NAIMUR RAHMAN, &#13;
Student ID: 1708105, &#13;
Session: 2021-2022, &#13;
DEPARTMENT OF PHYSICS; &#13;
HAJEE MOHAMMAD DANESH SCIENCE AND TECHNOLOGY UNIVERSITY, &#13;
DINAJPUR-5200; &#13;
BANGLADESH.
</description>
<pubDate>Wed, 01 Jan 2025 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://103.7.193.12:8080/xmlui/handle/123456789/2254</guid>
<dc:date>2025-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>CTDI Volume Measurement of CT Simulation and CT Effective Dose Calculation for  Cervix and Prostate</title>
<link>http://103.7.193.12:8080/xmlui/handle/123456789/2247</link>
<description>CTDI Volume Measurement of CT Simulation and CT Effective Dose Calculation for  Cervix and Prostate
Sohag, Mahfuzur Rahman
The accurate measurement of Computed Tomography Dose Index (CTDI) volume and the &#13;
calculation of effective dose are crucial in optimizing patient safety and ensuring the efficacy &#13;
of CT simulations in radiation therapy. This study focuses on evaluating the CTDI volume &#13;
during CT simulations and calculating the effective dose for patients undergoing treatment &#13;
for cervical and prostate cancers. By using phantoms and patient-specific data, this study &#13;
aims to quantify the radiation dose distribution and assess the potential risks associated with &#13;
these diagnostic procedures. The present retrospective study was conducted on 53 cervical &#13;
and prostate cancer patients (6 prostate and 47 cervical) with ages ranging from 35 to 75 &#13;
years. The examinations were carried out using a Philips Ingenuity Time-of-Flight (ToF) 64&#13;
slice PET/CT system (Philips Healthcare, Cleveland, OH, USA) at the Institute of Nuclear &#13;
Medical Physics, Atomic Energy Research Establishment (AERE), Savar, Dhaka. The scans &#13;
were performed according to institutional protocols. Dose measurements were carried out in &#13;
terms of CTDI100. CTDI100 values for the center and periphery of the phantom were recorded, &#13;
and the average value of the periphery doses was taken. Then, CTDIw was calculated using &#13;
CTDI100 values. Since an axial CT scan was taken on the phantom, there was no patient table &#13;
movement, making CTDIvol values the same as CTDIw values. The mean±SD CTDIvol was &#13;
obtained as 18.879±5.914 mGy, ranging from 8.952 to 37.327 mGy. The CT effective doses &#13;
were calculated using the dose conversion coefficient k=0.015 mSv.mGy-1.cm-1 for the pelvic &#13;
region, as described in the American Association of Physicists in Medicine Report No. 96. &#13;
The effective doses for the CT procedure were estimated using DLP values that represent &#13;
radiation exposure over the entire scan length. The scan lengths were generated by the &#13;
scanner, and the DLP values were measured as the product of CTDIvol and scan length. The &#13;
DLP values ranged from 411.225 to 2030.96 mGy·cm, with a mean value of &#13;
1094.479±462.029 mGy·cm. The effective dose is the product of the DLP and the conversion &#13;
coefficient k. The mean effective dose for the pelvic region was 16.271±7.180 mSv. The &#13;
doses for prostate patients were 15.125±8.815 mSv, and for cervical patients, they were &#13;
16.417±8.930 mSv. The present study found these values to be moderately higher compared &#13;
to the effective dose values of conventional diagnostic radiology examinations. This is &#13;
because the CT scans were performed on the patients as part of radiotherapy treatment &#13;
planning, and the scan lengths were longer than the pelvic region, resulting in higher effective &#13;
doses. However, this study suggests that the risk-benefit ratio of any radiological scan should &#13;
be clarified and carefully weighed.
CTDI Volume Measurement of CT Simulation and CT Effective Dose Calculation for &#13;
Cervix and Prostate;&#13;
Submitted by &#13;
Mahfuzur Rahman Sohag,&#13;
Student ID: 1708109, &#13;
Session: 2021-2022;&#13;
MS Student &#13;
Department of Physics, &#13;
HSTU, Dinajpur-5200, Bangladesh;
</description>
<pubDate>Mon, 01 Jul 2024 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://103.7.193.12:8080/xmlui/handle/123456789/2247</guid>
<dc:date>2024-07-01T00:00:00Z</dc:date>
</item>
</channel>